Find a Tender
complete
Official procurement procedure
Shielded High Resolution Gamma Spectrometry Portable System
Miscellaneous evaluation or testing instruments
Published value
Not published
Submission deadline Not published
Lots published1
Procurement Executive Summary
AI & Search Synopsis
Generated from official OCDS record
Tenderline Synopsis: Dounreay a Division of Magnox Limited: "Shielded High Resolution Gamma Spectrometry Portable System". Published status: complete. Published value: Value not published. 1 published lot. Submission deadline not published. See the official notice for participation instructions.
| Contracting Authority | Dounreay a Division of Magnox Limited | Scope & Categories | Not published | Submission Window | complete No deadline published |
|---|---|---|---|---|---|
| Submission Gateway | Direct notice route | Legal Basis & Regime | Standard procurement | Estimated Value (exc. VAT) | Not published |
Bidder Intelligence · Authority Profile: Dounreay a Division of Magnox Limited
Market Analytics
Derived from OCDS awards & bid statistics
Published history for Dounreay a Division of Magnox Limited. These figures describe retained records, not a forecast of bids or a measure of buyer bias.
Average Price Reduction
Not availableInsufficient comparable data
Competition Density
1.3Bids / Report
Supplier ConcentrationNo estimate
Insufficient attributable awardsNo concentration estimate availablePayment Terms
Check noticePublished terms
Coverage: 7 active published awards; 4 bid reports (which may be per lot). Supplier values exclude multi-supplier awards, frameworks and DPS, and use GBP only. They are published award values, not payments. Price reduction compares single-lot, single-award, single-supplier GBP procedures with explicitly non-framework/non-DPS status; increases remain in the average. Unpublished data stays unknown. Awarded suppliers are winners, not all bidders.
Procedure terms
Contracting AuthorityDounreay a Division of Magnox Limited | Procedure methodNot published | Procurement categoryNot published |
Statuscomplete | Framework / DPSNot published | CompetitionNot published |
Above thresholdNot published | Legal basisNot published | Tender period startsNot published |
Clarification deadlineNot published | Electronic submissionNot published | Submission languagesNot published |
Published1 Feb 2024, 17:27 GMT | Last source update1 Feb 2024, 17:27 GMT | Recurring procurementNot published |
ClassificationMiscellaneous evaluation or testing instruments | ||
Delivery area | ||
OCIDocds-h6vhtk-043689 | ||
What is being bought
Shielded High Resolution Gamma Spectrometry Portable System
What changed
From the official release history
- Status changed to complete
1 Feb 2024, 17:27 GMT - Official notice release published
1 Feb 2024, 17:27 GMT - Buyer information updated
1 Feb 2024, 17:27 GMT
Lots and requirements (1)
Published by the contracting authority
- Lot 1 · #1Individual lot title not publishedcancelledPublished valueNot publishedShielded High Resolution Gamma Spectrometry Portable SystemContract periodNot publishedEligibilityNot publishedOptions / renewalNot published
Timeline
- Procedure published
1 Feb 2024, 17:27 GMT - Award active
Not published · Not published - Contract active
Signed 18 Dec 2023, 00:00 GMT · £278,800
Commercial outcome and competition
Awards Southern Scientific Ltd Not published · Not published · active |
Contracts Contract £278,800 · signed 18 Dec 2023, 00:00 GMT · active |
Bid statistics bids: 1 (lot 1) electronicBids: 1 (lot 1) foreignBidsFromEU: 0 (lot 1) foreignBidsFromNonEU: 0 (lot 1) smeBids: 1 (lot 1) |
Buyer and organisations in this procedure
Dounreay a Division of Magnox Limited
Contracting authority GB-FTS-93949Documents (0)
Official links; attachments are not copied
No linked documents are published
Related procedures (0)
No related procedures published
Planning and rationale
Planning budgetNot published |
No-engagement rationaleNot published |
Procedure rationaleThe functional specification is for a hand held gamma imagining detector, that in a single measurement event, is able to map and quantify radionuclides in the area of measurement.<br/><br/>The H3D H420+ detector is the only commercially available system that is able to meet this functional specification, which includes a spectral range of 50keV to 3 meV and a Full Width Half Maximum at 662 keV (Cs-137) better than 0.8%. This functional specification is required for the complex radionuclide ‘fingerprints’ on the Dounreay site.<br/><br/>The technology is patented (ref U.S. Pat No. 7,411,197 and U.S. Pat No. 7,962,155 under licence from the University of Michigan, and U.S. Pat No. 10,032,264 and U.S, Pat No. 10,297,697). |