Find a Tender
complete
Official procurement procedure
Accurate Mass Gas Chromatograph Mass Spectrometer (Orbitrap)
Gas chromatographs
Mass spectrometer
Published value
Not published
Submission deadline Not published
Lots published1
Procurement Executive Summary
AI & Search Synopsis
Generated from official OCDS record
Tenderline Synopsis: Durham University: "Accurate Mass Gas Chromatograph Mass Spectrometer (Orbitrap)". Published status: complete. Published value: Value not published. 1 published lot. Submission deadline not published. See the official notice for participation instructions.
| Contracting Authority | Durham University | Scope & Categories | Not published | Submission Window | complete No deadline published |
|---|---|---|---|---|---|
| Submission Gateway | Direct notice route | Legal Basis & Regime | Standard procurement | Estimated Value (exc. VAT) | Not published |
Bidder Intelligence · Authority Profile: Durham University
Market Analytics
Derived from OCDS awards & bid statistics
Published history for Durham University. These figures describe retained records, not a forecast of bids or a measure of buyer bias.
Published-to-award variance
Not availableInsufficient comparable data
Competition Density
6Bids / Report
Supplier ConcentrationNo estimate
Insufficient attributable awardsNo concentration estimate availablePayment Terms
Check noticePublished terms
Coverage: 6 active published awards; 1 bid reports (which may be per lot). Supplier values exclude multi-supplier awards, frameworks and DPS, and use GBP only. They are published award values, not payments. Published-to-award variance compares single-lot, single-award, single-supplier GBP procedures with explicitly non-framework/non-DPS status; increases remain in the average. Unpublished data stays unknown. Awarded suppliers are winners, not all bidders.
Procedure terms
Contracting AuthorityDurham University | Procedure methodNot published | Procurement categoryNot published |
Statuscomplete | Framework / DPSNot published | CompetitionNot published |
Above thresholdNot published | Legal basisNot published | Tender period startsNot published |
Clarification deadlineNot published | Electronic submissionNot published | Submission languagesNot published |
Published8 Dec 2022, 16:31 GMT | Last source update8 Dec 2022, 16:31 GMT | Recurring procurementNot published |
ClassificationGas chromatographs, Mass spectrometer | ||
Delivery area | ||
OCIDocds-h6vhtk-038c06 | ||
What is being bought
The University has a requirement to purchase an Orbitrap Gas Chromatograph Mass Spectrometer (GC-MS) with liquid, headspace and SPME arrow sample introduction systems. The instrument will be situated in the geography laboratories and will support researchers in multiple departments.
The University has published this VEAT notice and intends to award a contract to Themo Fisher Scientific, following the expiry of 10 days from the date of publication of this notice.
What changed
From the official release history
- Status changed to complete
8 Dec 2022, 16:31 GMT - Official notice release published
8 Dec 2022, 16:31 GMT - Buyer information updated
8 Dec 2022, 16:31 GMT
Lots and requirements (1)
Published by the contracting authority
- Lot 1 · #1Individual lot title not publishedStatus not publishedPublished valueNot publishedThe University has a requirement to purchase a high-resolution accurate mass Orbitrap Gas Chromatograph Mass Spectrometer (GC-MS) with liquid, headspace and SPME arrow sample introduction systems. The Orbitrap GCMS must have the capability for highly accurate and reproducible identification, quantification, and tracing of individual organic compounds with known sources or pathways, from a wide variety of environments and sample types. The instrument must be supplied with computer hardware and software capable of operating the instrument and data processing/analysis. The University has published this VEAT notice and intends to award a contract to Thermo Fisher Scientific, following the expiry of 10 days from the date of publication of this notice.Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
Timeline
- Procedure published
8 Dec 2022, 16:31 GMT - Award active
Not published · Not published - Contract active
Signed 8 Dec 2022, 00:00 GMT · £391,666
Commercial outcome and competition
Awards Thermo Electron Manufacturing Limited T/A Thermo Fisher Scientific Not published · Not published · active |
Contracts Accurate Mass Gas Chromatograph Mass Spectrometer (Orbitrap) £391,666 · signed 8 Dec 2022, 00:00 GMT · active |
Bid statisticsNo aggregate bid statistics published |
Buyer and organisations in this procedure
Durham University
Contracting authority GB-COH-RC000650Documents (0)
Official links; attachments are not copied
No linked documents are published
Related procedures (0)
No related procedures published
Planning and rationale
Planning budgetNot published |
No-engagement rationaleNot published |
Procedure rationaleThe system must have the following key features:
• A 60,000 resolution (Full Width Half Max m/z 200) system, capable of switching dynamically between full scan and Selected Ion Mode (SIM) mode.
• Mass range of m/z 30 - 2000.
• High sensitivity due to the low concentration of target molecules in environmental samples.
Electron Ionisation: 100 fg octafluoronaphthalene on column, scanning m/z 50-300, S/N 10,000:1
Electron Ionisation Instrument Detection Limit: 6 fg octafluoronaphthalene derived at the 99% confidence level
Positive Chemical Ionisation: 10 pg benzophenone on column, scanning m/z 80-230, S/N 150:1
• Vent free analytical column and ion source/lens exchange.
• Variable electron energy acquisition for increased molecular ion production.
• High mass accuracy below 2 ppm.
• A bench top system with a height of no more than 1000 mm.
• An interchangeable integrated sample introduction system (liquid, headspace and SPME arrow).
• Fast MS/MS scan speeds (e.g. 7.5 Hz at 60,000), to allow for high throughput sample analyses.
• Software capable of performing targeted and non-targeted analysis of complex environmental samples.
• MS/MS and chemical ionisation for confirmation of molecular ion.
• Compatibility with existing software systems (Chromeleon).
• Compatibility with existing Thermo Scientific GC / GCMS systems to allow interchange of injector modules and parts (e.g. Programable Temperature Vaporisation, split/splitless, ion volumes) |