Unmodified official OCDS data retained by Tenderline for this procurement process.
Complete current OCDS release JSON
{
"id": "002057-2023",
"tag": [
"award",
"contract"
],
"bids": {
"statistics": [
{
"id": "1",
"value": 2254326.75,
"measure": "lowestValidBidValue",
"currency": "EUR",
"relatedLot": "1"
},
{
"id": "2",
"value": 2254326.75,
"measure": "highestValidBidValue",
"currency": "EUR",
"relatedLot": "1"
}
]
},
"date": "2023-01-23T16:45:27Z",
"ocid": "ocds-h6vhtk-0399e3",
"buyer": {
"id": "GB-FTS-155",
"name": "National Physical Laboratory"
},
"awards": [
{
"id": "002057-2023-1",
"status": "active",
"suppliers": [
{
"id": "GB-FTS-73480",
"name": "IONTOF GmbH"
}
],
"relatedLots": [
"1"
],
"hasSubcontracting": true
}
],
"tender": {
"id": "ocds-h6vhtk-0399e3",
"lots": [
{
"id": "1",
"hasOptions": false,
"description": "The OrbiSIMS instrument shall be equipped with a time-of-flight mass spectrometer (ToF) for high-speed imaging of large areas or in 3D. It shall also be equipped with a high-field Orbitrap mass spectrometer with a mass resolving power of >240,000 at m/z 200 and a mass accuracy of ~ 1 ppm. The instrument shall be equipped with 3 primary ion beams which are optimal for different materials systems. (1) A 20 kV gas cluster ion source with a spatial resolution < 2 µm used for biological imaging and depth-profiling of organic materials, (2) a low energy (250 eV to 2000 eV) dual source (Cs and O2) sputter beam with high-current (>50 nA at 500 eV with a spatial resolution < 40 µm) for depth profiling of semiconductor samples and (3) a 30 kV high-resolution Bi nanoprobe with a spatial resolution < 50 nm. The instrument shall be able to operate with either the ToF analyser or the Orbitrap analyser or a combination of the two as described in the Nat. Methods paper. (4) a Ga focused ion beam with accelerating voltages of up to 30 kV, minimum bema diameter of 60nm and beam current > 25 nA. The OrbiSIMS shall be equipped for cryogenic analysis (sample holder temperature < -150 oC) and be compatible with and including Leica sample holders and allow the docking of a Leica VCT-500 cryo transfer vessel. It shall have two high-resolution TV cameras for direct sample observation and rapid location of the area of interest, as well as a photo box for high-resolution sample navigation. In addition to mass analysers, the instrument shall have a pulsed high-quality Everhart-Thornley secondary electron detector, located at grazing incidence to the sample, for primary ion induced secondary electron imaging and a self-adjusting charge compensation system using a pulsed, low energy electron flood gun. Samples shall be mounted using a rapid sample introduction system, with one sample holder for rear mounting of up to 18 samples with maximum dimensions of 10 mm x 10 mm x 8 mm, including mounting accessories, one sample holder for top mounting of multiple samples on an area of 100 mm x 80 mm with a maximum thickness of up to 20 mm, and one sample holder for mounting samples for cryogenic analysis."
}
],
"items": [
{
"id": "1",
"relatedLot": "1",
"deliveryAddresses": [
{
"region": "UK"
}
]
}
],
"title": "OrbiSIMS – simultaneous high-mass resolving power and high-spatial resolution mass spectrometry imaging for biological and advanced materials characterisation",
"status": "complete",
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
},
"description": "NPL pioneered the next generation OrbiSIMS technology introduced in detail in Nature Methods (2017, PMID: 29131162). The instrument is equipped with a time-of-flight mass spectrometer (ToF) for high-speed imaging of large areas or in 3D. It is also equipped with a high-field Orbitrap mass spectrometer with a mass resolving power of >240,000 at m/z 200 and a mass accuracy of approximately 1 ppm. Both ToF and Orbitrap analysers can be used simultaneously or separately. The OrbiSIMS shall be able to carry out cryogenic analysis under ultra-high vacuum with sample holder temperatures below –150 oC.",
"classification": {
"id": "38000000",
"scheme": "CPV",
"description": "Laboratory, optical and precision equipments (excl. glasses)"
},
"procurementMethod": "limited",
"mainProcurementCategory": "goods",
"procurementMethodDetails": "Award procedure without prior publication of a call for competition",
"procurementMethodRationale": "The OrbiSIMS concept was created at NPL and the first prototype instrument was built in a collaborative project with IONTOF and ThermoFisher Scientific. The instrument was subsequently commercialised by IONTOF and sold as the Hybrid SIMS. IONTOF are the only manufacturer of this type of instrument. A number of features of the OrbiSIMS instrument are protected by international patents. Unique features of the OrbiSIMS instrument include: \n1.\tImaging of biomolecules from tissue using a gas cluster ion beam with a spatial resolution of < 2 µm simultaneously with a mass resolving power of > 240,000 at m/z 200.\n2.\tDepth resolution of < 10 nm of organic molecules in an organic multilayer reference sample simultaneously with a mass resolving power of > 240,000 at m/z 200.\n3.\tDepth resolution of < 2 nm of ions in an inorganic semiconductor delta-layer reference sample simultaneously with a mass resolving power of > 240,000 at m/z 200.\n4.\tCryogenic imaging (see requirement 1) with a sample holder temperature of < -150 oC. Samples shall be mounted on Leica sample mounts. The instrument shall accept docking of a Leica VCT-500 cryo transfer vessel and have provision to receive samples into the instrument.",
"procurementMethodRationaleClassifications": [
{
"id": "D_OUTSIDE_SCOPE",
"scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL",
"description": "The procurement falls outside the scope of application of the directive"
}
]
},
"parties": [
{
"id": "GB-FTS-155",
"name": "National Physical Laboratory",
"roles": [
"buyer"
],
"address": {
"region": "UK",
"locality": "Teddington",
"postalCode": "TW11 0LW",
"countryName": "United Kingdom",
"streetAddress": "Hampton Road"
},
"details": {
"url": "http://www.npl.co.uk",
"classifications": [
{
"id": "BODY_PUBLIC",
"scheme": "TED_CA_TYPE",
"description": "Body governed by public law"
},
{
"scheme": "COFOG",
"description": "Research"
}
]
},
"identifier": {
"legalName": "National Physical Laboratory"
},
"contactPoint": {
"name": "Mandy Morgan",
"email": "mandy.morgan@npl.co.uk",
"telephone": "+44 2089436731"
}
},
{
"id": "GB-FTS-73480",
"name": "IONTOF GmbH",
"roles": [
"supplier"
],
"address": {
"region": "DE",
"locality": "Munster",
"postalCode": "48149",
"countryName": "Germany",
"streetAddress": "Heisenbergstr 15"
},
"details": {
"scale": "large"
},
"identifier": {
"legalName": "IONTOF GmbH"
}
},
{
"id": "GB-FTS-156",
"name": "NPL Management Ltd",
"roles": [
"reviewBody"
],
"address": {
"locality": "Teddington",
"postalCode": "TW11 0LW",
"countryName": "United Kingdom",
"streetAddress": "Hampton Road"
},
"identifier": {
"legalName": "NPL Management Ltd"
}
}
],
"language": "en",
"contracts": [
{
"id": "002057-2023-1",
"status": "active",
"awardID": "002057-2023-1",
"dateSigned": "2023-01-23T00:00:00Z"
}
],
"initiationType": "tender"
}Complete JSON history (1 releases)
23 Jan 2023 · 002057-2023 · award, contract
{
"id": "002057-2023",
"tag": [
"award",
"contract"
],
"bids": {
"statistics": [
{
"id": "1",
"value": 2254326.75,
"measure": "lowestValidBidValue",
"currency": "EUR",
"relatedLot": "1"
},
{
"id": "2",
"value": 2254326.75,
"measure": "highestValidBidValue",
"currency": "EUR",
"relatedLot": "1"
}
]
},
"date": "2023-01-23T16:45:27Z",
"ocid": "ocds-h6vhtk-0399e3",
"buyer": {
"id": "GB-FTS-155",
"name": "National Physical Laboratory"
},
"awards": [
{
"id": "002057-2023-1",
"status": "active",
"suppliers": [
{
"id": "GB-FTS-73480",
"name": "IONTOF GmbH"
}
],
"relatedLots": [
"1"
],
"hasSubcontracting": true
}
],
"tender": {
"id": "ocds-h6vhtk-0399e3",
"lots": [
{
"id": "1",
"hasOptions": false,
"description": "The OrbiSIMS instrument shall be equipped with a time-of-flight mass spectrometer (ToF) for high-speed imaging of large areas or in 3D. It shall also be equipped with a high-field Orbitrap mass spectrometer with a mass resolving power of >240,000 at m/z 200 and a mass accuracy of ~ 1 ppm. The instrument shall be equipped with 3 primary ion beams which are optimal for different materials systems. (1) A 20 kV gas cluster ion source with a spatial resolution < 2 µm used for biological imaging and depth-profiling of organic materials, (2) a low energy (250 eV to 2000 eV) dual source (Cs and O2) sputter beam with high-current (>50 nA at 500 eV with a spatial resolution < 40 µm) for depth profiling of semiconductor samples and (3) a 30 kV high-resolution Bi nanoprobe with a spatial resolution < 50 nm. The instrument shall be able to operate with either the ToF analyser or the Orbitrap analyser or a combination of the two as described in the Nat. Methods paper. (4) a Ga focused ion beam with accelerating voltages of up to 30 kV, minimum bema diameter of 60nm and beam current > 25 nA. The OrbiSIMS shall be equipped for cryogenic analysis (sample holder temperature < -150 oC) and be compatible with and including Leica sample holders and allow the docking of a Leica VCT-500 cryo transfer vessel. It shall have two high-resolution TV cameras for direct sample observation and rapid location of the area of interest, as well as a photo box for high-resolution sample navigation. In addition to mass analysers, the instrument shall have a pulsed high-quality Everhart-Thornley secondary electron detector, located at grazing incidence to the sample, for primary ion induced secondary electron imaging and a self-adjusting charge compensation system using a pulsed, low energy electron flood gun. Samples shall be mounted using a rapid sample introduction system, with one sample holder for rear mounting of up to 18 samples with maximum dimensions of 10 mm x 10 mm x 8 mm, including mounting accessories, one sample holder for top mounting of multiple samples on an area of 100 mm x 80 mm with a maximum thickness of up to 20 mm, and one sample holder for mounting samples for cryogenic analysis."
}
],
"items": [
{
"id": "1",
"relatedLot": "1",
"deliveryAddresses": [
{
"region": "UK"
}
]
}
],
"title": "OrbiSIMS – simultaneous high-mass resolving power and high-spatial resolution mass spectrometry imaging for biological and advanced materials characterisation",
"status": "complete",
"legalBasis": {
"id": "32014L0024",
"scheme": "CELEX"
},
"description": "NPL pioneered the next generation OrbiSIMS technology introduced in detail in Nature Methods (2017, PMID: 29131162). The instrument is equipped with a time-of-flight mass spectrometer (ToF) for high-speed imaging of large areas or in 3D. It is also equipped with a high-field Orbitrap mass spectrometer with a mass resolving power of >240,000 at m/z 200 and a mass accuracy of approximately 1 ppm. Both ToF and Orbitrap analysers can be used simultaneously or separately. The OrbiSIMS shall be able to carry out cryogenic analysis under ultra-high vacuum with sample holder temperatures below –150 oC.",
"classification": {
"id": "38000000",
"scheme": "CPV",
"description": "Laboratory, optical and precision equipments (excl. glasses)"
},
"procurementMethod": "limited",
"mainProcurementCategory": "goods",
"procurementMethodDetails": "Award procedure without prior publication of a call for competition",
"procurementMethodRationale": "The OrbiSIMS concept was created at NPL and the first prototype instrument was built in a collaborative project with IONTOF and ThermoFisher Scientific. The instrument was subsequently commercialised by IONTOF and sold as the Hybrid SIMS. IONTOF are the only manufacturer of this type of instrument. A number of features of the OrbiSIMS instrument are protected by international patents. Unique features of the OrbiSIMS instrument include: \n1.\tImaging of biomolecules from tissue using a gas cluster ion beam with a spatial resolution of < 2 µm simultaneously with a mass resolving power of > 240,000 at m/z 200.\n2.\tDepth resolution of < 10 nm of organic molecules in an organic multilayer reference sample simultaneously with a mass resolving power of > 240,000 at m/z 200.\n3.\tDepth resolution of < 2 nm of ions in an inorganic semiconductor delta-layer reference sample simultaneously with a mass resolving power of > 240,000 at m/z 200.\n4.\tCryogenic imaging (see requirement 1) with a sample holder temperature of < -150 oC. Samples shall be mounted on Leica sample mounts. The instrument shall accept docking of a Leica VCT-500 cryo transfer vessel and have provision to receive samples into the instrument.",
"procurementMethodRationaleClassifications": [
{
"id": "D_OUTSIDE_SCOPE",
"scheme": "TED_PT_AWARD_CONTRACT_WITHOUT_CALL",
"description": "The procurement falls outside the scope of application of the directive"
}
]
},
"parties": [
{
"id": "GB-FTS-155",
"name": "National Physical Laboratory",
"roles": [
"buyer"
],
"address": {
"region": "UK",
"locality": "Teddington",
"postalCode": "TW11 0LW",
"countryName": "United Kingdom",
"streetAddress": "Hampton Road"
},
"details": {
"url": "http://www.npl.co.uk",
"classifications": [
{
"id": "BODY_PUBLIC",
"scheme": "TED_CA_TYPE",
"description": "Body governed by public law"
},
{
"scheme": "COFOG",
"description": "Research"
}
]
},
"identifier": {
"legalName": "National Physical Laboratory"
},
"contactPoint": {
"name": "Mandy Morgan",
"email": "mandy.morgan@npl.co.uk",
"telephone": "+44 2089436731"
}
},
{
"id": "GB-FTS-73480",
"name": "IONTOF GmbH",
"roles": [
"supplier"
],
"address": {
"region": "DE",
"locality": "Munster",
"postalCode": "48149",
"countryName": "Germany",
"streetAddress": "Heisenbergstr 15"
},
"details": {
"scale": "large"
},
"identifier": {
"legalName": "IONTOF GmbH"
}
},
{
"id": "GB-FTS-156",
"name": "NPL Management Ltd",
"roles": [
"reviewBody"
],
"address": {
"locality": "Teddington",
"postalCode": "TW11 0LW",
"countryName": "United Kingdom",
"streetAddress": "Hampton Road"
},
"identifier": {
"legalName": "NPL Management Ltd"
}
}
],
"language": "en",
"contracts": [
{
"id": "002057-2023-1",
"status": "active",
"awardID": "002057-2023-1",
"dateSigned": "2023-01-23T00:00:00Z"
}
],
"initiationType": "tender"
}