Enhanced Chemical Analysis for Copper Sulphate
Laboratory services
UK
Published value
Not published
Submission deadline Not published
Lots published6
Procurement Executive Summary
AI & Search Synopsis
Generated from official OCDS record
Tenderline Synopsis: NHS Blood & Transplant: "Enhanced Chemical Analysis for Copper Sulphate". Published status: planned. Published value: Value not published. 6 published lots. Submission deadline not published. See the official notice for participation instructions.
| Contracting Authority | NHS Blood & Transplant | Scope & Categories | Not published | Submission Window | planned No deadline published |
|---|---|---|---|---|---|
| Submission Gateway | Direct notice route | Legal Basis & Regime | Standard procurement | Estimated Value (exc. VAT) | Not published |
Bidder Intelligence · Authority Profile: NHS Blood & Transplant
Market Analytics
Derived from OCDS awards & bid statistics
Published history for NHS Blood & Transplant. These figures describe retained records, not a forecast of bids or a measure of buyer bias.
Published-to-award variance
Not availableInsufficient comparable data
Competition Density
2Bids / Report
Supplier ConcentrationNo estimate
Insufficient attributable awardsNo concentration estimate availablePayment Terms
Check noticePublished terms
Coverage: 14 active published awards; 14 bid reports (which may be per lot). Supplier values exclude multi-supplier awards, frameworks and DPS, and use GBP only. They are published award values, not payments. Published-to-award variance compares single-lot, single-award, single-supplier GBP procedures with explicitly non-framework/non-DPS status; increases remain in the average. Unpublished data stays unknown. Awarded suppliers are winners, not all bidders.
Procedure terms
Contracting AuthorityNHS Blood & Transplant | Procedure methodNot published | Procurement categoryNot published |
Statusplanned | Framework / DPSNot published | CompetitionNot published |
Above thresholdNot published | Legal basisNot published | Tender period startsNot published |
Clarification deadlineNot published | Electronic submissionNot published | Submission languagesNot published |
Published11 Feb 2021, 22:56 GMT | Last source update11 Feb 2021, 22:56 GMT | Recurring procurementNot published |
ClassificationLaboratory services | ||
Delivery area UK | ||
OCIDocds-h6vhtk-029289 | ||
What is being bought
NHSBT are seeking an enhanced analysis of Copper Sulphate solution which is an in vitro, semi-quantitative reagent used for investigation on the acceptance of blood donor minimum haemoglobin levels when taken from a capillary blood sample. The reagent is used to test a droplet of blood from a donor’s finger, following the use of a lancet, which will be transferred into the solution using a pipette.
NHSBT must update the product conformity profile for this device and must understand the impact when exposed to different variables throughout its formulation process, transportation, use and storage. The profile is to be produced through a number of studies for visual, chemical and therapeutic analysis. In current practice, NHSBT Copper Sulphate solutions are used professionally for male and female specific testing to ensure only suitable donors are bled. Therefore, all studies must be conducted for scenario 1) Female Donation and Scenario 2) Male Donation.
What changed
From the official release history
- Status changed to planned
11 Feb 2021, 22:56 GMT - Official notice release published
11 Feb 2021, 22:56 GMT - Buyer information updated
11 Feb 2021, 22:56 GMT
Lots and requirements (6)
Published by the contracting authority
- Lot 1 · #1Study 1 - Assessment of products useful lifeplannedPublished valueNot publishedStudy 1 - Assessment of products useful life This is to be determined through the maximum number of drops of blood that can be added to the copper sulphate before the product returns an inaccurate result under varying conditions.Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
- Lot 2 · #2Study 2 - Assessment of the device’s stability during shelf lifeplannedPublished valueNot publishedStudy 2 - Assessment of the device’s stability during shelf life During routine storage at what point does the device start to fail: (a) Visually (i) Photostability storage study (ii) Integrity of the labels when exposed to routine use, light. (b) Chemically (i) Chemical analysis storage study (ii)Theoretical analysis of formula to outline potential chemical interactions that may degrade over time.Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
- Lot 3 · #3Study 3 - Bacterial contaminationplannedPublished valueNot publishedStudy 3 - Bacterial contamination (a) During routine storage, at what point does bacterial ingress occur – Bacterial storage study to be conducted on fresh and end of shelf life product. (b) If the product is challenged with routine environmental microbiological contaminants does this result in proliferation of the contaminants? - Controlled bacterial challenge study conducted on fresh and end of shelf life product.Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
- Lot 4 · #4Study 4 – PackagingplannedPublished valueNot publishedStudy 4 – Packaging Study to challenge the packaging to address the impact and potential for: (a) Product leakage (b) Product damage – Physical and degradation of the bottles and or seal (c) Product evaporation (d) Electrostatic impacts (from packaging material)Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
- Lot 5 · #5Study 5 – Health and SafetyplannedPublished valueNot publishedStudy 5 – Health and Safety Health and safety evaluation in accordance with Directive: (a) Risk to individuals (b) Appropriate method of discard (c) Shipping and Transportation recommendationsContract periodNot publishedEligibilityNot publishedOptions / renewalNot published
- Lot 6 · #6Study 6 – Impacts to Specific GravityplannedPublished valueNot publishedStudy 6 – Impacts to Specific Gravity Assessment of the impact of temperature on the specific gravity of the device: (a) Theoretical analysis of the device to calculate in the potential changes in Specific gravity that could occur under routine storage conditions (b) Study protocol to test the male and female device for specific gravity under a range of routine storage temperatures and in use parametersContract periodNot publishedEligibilityNot publishedOptions / renewalNot published
Timeline
- Procedure published
11 Feb 2021, 22:56 GMT
Commercial outcome and competition
AwardsNo award published |
ContractsNo contract published |