Chemical Ionisation Mass Spectrometer

Official notice

Authority: UNIVERSITY OF MANCHESTER (Education)

GoodsAward procedure without prior publication of a call for competition
Budget not disclosedValue not published
Awarded 19 Dec 2022no call for competition
Awarded to Aerodyne Research, Inc.,2 awards

What is being bought

Published requirement description

The University intends to acquire a Chemical Ionisation (CI)-Time of Flight (ToF) is an ultrasensitive mass spectrometer The Centre for Atmospheric Sciences (CAS) at the University of Manchester is interested in a wide range of environmental science challenges, which involve under-standing the transfer of molecules between gas, liquid and solid phases.

CPV: Mass spectrometer

The lotProcurement structure

single lot · no lot value published
Lot #1Awarded
Delivery: North West · The University of Manchester

Procedure terms & legal framework

From the official record
Procedure method
Award procedure without prior publication of a call for competition
Legal basis
CELEX · 32014L0024 Public Contracts Regulations 2015 (Directive 2014/24/EU)
Procurement category
Goods
Notice status
Awarded without competition
Procurement threshold
Unspecified in notice
Regulatory regime
Standard
Commercial structure
Stand-alone contract (no framework)
Competition type
Direct award (no call for competition)
GPA / WTO covered
Yes (GPA)
Recurring procurement
Unspecified in notice
First published
7 Dec 2022, 15:37 GMT
Last source update
19 Dec 2022, 08:38 GMT
Authority reference
2022/1973/CIMS/HC
FTS notice number
2022/S 000-035771
Classification (CPV)
Mass spectrometer
Delivery area
North West (UKD3)
Official registry OCID
ocds-h6vhtk-038b84 Find a Tender
Why no open competition

The works, supplies or services can be provided only by a particular economic operator due to absence of competition for technical reasons

Published justification

A CI-TOF is an ultra-sensitive mass spectrometer for the online characterization of trace gases and aerosols in complex mixtures. This instrument will provide a high-resolution time of-flight mass spectrometer with bipolar power supply for positive or negative ion detection with interchangeable reactors for a full range of measurement options over an extensive volatility range. Interchange of these chemical ionization ion-molecule reactors will be possible while maintaining the operating pressure of the interface and TOF chambers . This instrument will provide

simultaneous switching between multiple (three or less) reagent ions of the same polarity with the PTR and AIM reactors and have the capability to connect reactors to inlets that allows for particulate and gas phase compositions in real time (VIA

inlet (PTR reactor), FIGAERO Inlet (AIM reactor)). This instrument will also provide an Extractive Electrospray (EESI) inlet that allows for detection of particle phase components without thermal vaporization.

Key performance specifications are: Sensitivity with PTR Reactor (xylene): 30001 cps/ppb at specified mass resolving power of 10,000. Sensitivity with Aim Reactor (levoglucosan): 30001 cps/ppb at specified mass resolving power. Limits of detection PTR Reactor (3 sigma LOD, xylene): 1E4 in 1 second Time response.

Commercial outcome & contract awards

Published awards, contracts and bid statistics, not a forecast
Awards 2
Bids received 1
Contracts signed 2latest 19 Dec 2022
Awarded toValueDateStatus
Aerodyne Research, Inc.,US$762,430 †same award published again · counted once—Awarded
Aerodyne Research, Inc.,US$762,430 †—Awarded

Contracts

Bid statistics published by the authority

BidsSMEVCSEValid bid range
1bids———

Contracting authority & participating public bodies

UNIVERSITY OF MANCHESTER

Contracting authorityEducationBody governed by public lawEducation GB-UKPRN: 10007798 Room G010,John Owens Building, Oxford Road, MANCHESTER, North West, M139PLContact name, email, phone

Dispute resolution & review bodies

Bidders & participating suppliers

1 commercial party on the notice

Official documents & specifications

Official links; attachments are not copied

No document links were published on the notice.