Tenderline Synopsis: Secretary of State for Health and Social Care acting as part of the Crown through UK Health Security Agency: "Bespoke MSCIII cabinet". Published status: planned. Published value: £50,000. 1 published lot. Submission deadline not published. See the official notice for participation instructions.
| Contracting Authority | Secretary of State for Health and Social Care acting as part of the Crown through UK Health Security Agency | Scope & Categories | Not published | Submission Window | planned No deadline published |
|---|---|---|---|---|---|
| Submission Gateway | Direct notice route | Legal Basis & Regime | Standard procurement | Estimated Value (exc. VAT) | £50,000 |
Bidder Intelligence · Authority Profile: Secretary of State for Health and Social Care acting as part of the Crown through UK Health Security Agency
Market Analytics
Derived from OCDS awards & bid statistics
Published history for Secretary of State for Health and Social Care acting as part of the Crown through UK Health Security Agency. These figures describe retained records, not a forecast of bids or a measure of buyer bias.
Average Price Reduction
Not availableInsufficient comparable data
Competition Density
1.5Bids / Report
Supplier ConcentrationNo estimate
Insufficient attributable awardsNo concentration estimate availablePayment Terms
Check noticePublished terms
Coverage: 125 active published awards; 77 bid reports (which may be per lot). Supplier values exclude multi-supplier awards, frameworks and DPS, and use GBP only. They are published award values, not payments. Price reduction compares single-lot, single-award, single-supplier GBP procedures with explicitly non-framework/non-DPS status; increases remain in the average. Unpublished data stays unknown. Awarded suppliers are winners, not all bidders.
Procedure terms
Procedure methodNot published | Procurement categoryNot published | |
Statusplanned | Framework / DPSNot published | CompetitionNot published |
Above thresholdNot published | Legal basisNot published | Tender period startsNot published |
Clarification deadlineNot published | Electronic submissionNot published | Submission languagesNot published |
Published18 Dec 2023, 18:02 GMT | Last source update18 Dec 2023, 18:02 GMT | Recurring procurementNot published |
ClassificationMedical cultivation cabinet | ||
Delivery area | ||
OCIDocds-h6vhtk-0426a4 | ||
What is being bought
UKHSA Biosafety Group at Porton Down are looking for a bespoke class III safety cabinet. This equipment will be used for a range of activities including aerobiology and the test and validation of equipment and materials for commercial, research and incident response work. Whilst some of the work will be with pathogens and require a high level of containment, some of it will be using non-pathogenic agents, using the cabinet as a clean enclosure. This will include operation of the cabinet under conditions not normally used at CL3, such as working within the cabinet without the ventilation running.
What changed
From the official release history
- Published value updated to £50,000
18 Dec 2023, 18:02 GMT - Status changed to planned
18 Dec 2023, 18:02 GMT - Official notice release published
18 Dec 2023, 18:02 GMT - Buyer information updated
18 Dec 2023, 18:02 GMT
Lots and requirements (1)
Published by the contracting authority
- Lot 1 · #1Individual lot title not publishedplannedPublished valueNot publishedDue to the specific needs and requirements, the solution must comprise the following specifications:<br/>• Internal dimensions of 1600mm wide, 760mm deep and 820mm high.<br/>• Single, non-ventilated pass box. <br/>• Removable front window - being easily removed and replaced.<br/>• Window will have four 200 mm diameter glove ports (with a double o-ring attachment) at a standard height and 2 or 3 fitted in the top half of the window (position and number of ports will be determined and confirmed via simple mock-up).<br/>• Manufactured and tested in accordance to EN 12469:2000.<br/>• The air change rate within the cabinet must not be less than 6 meters cubed per minute for each cubic metre of cabinet volume.<br/>• The working pressure in the cabinet must not be less than -200 Pa (with respect to the laboratory). A manometer capable of measuring from -500 Pa to +500 Pa must be mounted on the cabinet to give a visual indication of the pressure in the interior.<br/>• The cabinet must be supplied with HEPA (High-efficiency particulate air) filtration to Class H-14 99,995% MPPS overall efficiency. Integrity testing of filters using Dispersed Oil Particulate (DOP) scanning of the downstream side of filters, seals, gaskets and construction joints must ensure that no leak penetrations produced are greater than 0.003% of the upstream challenge aerosol. <br/>• Cabinet must be fitted with double HEPA on exhaust. <br/>• Both HEPAs must be independently testable and must be mounted in accordance to section 7.5 of BS EN 12469:2000. <br/>• The cabinet must be fitted with injection and extraction ports for use with an external hydrogen peroxide fumigation systems (1¼” Camlock fittings). Injection to be through the inlet filter and removal post installed extract filters. <br/>• Connection to allow for monitoring of pressure.<br/>• The cabinet must be supplied with clear, easy to operate control panels, visible from the operators seated position and easy to access.<br/>• The main chamber will be fitted with 2 x 1¼” Camlock fittings and 2 compressed gas fittings with solenoid valve linked to alarms.<br/>• The main chamber will have an accessible, removable service plate 40cm x 20cm to allow for flexibility in the future to add additional services, initially provided with the following fittings; 2 compressed air fitting, 4 x 1 1/2” sanitary fitting, 4 x 8mm hose bar fittings, three USB connections, allowing space for future additional fittings as required. <br/>• Fasteners must be stainless steel grade (316). All internal surfaces and fittings should be easily cleanable, and suitably finished to minimise the possibility of damage to the cabinet gauntlets and to facilitate effective cleaning.<br/>• The cabinet must be fitted with 4 min no internal electrical sockets with the following requirements: <br/>- independently switchable; <br/>- 13 amp fused supply; <br/>- 1x Fumigation socket;<br/>- Installed in suitable positions to allow easy access during work (usually on the side panels);<br/>- Splash proof but sockets with fully sealed covers should be avoided;<br/>- Socket covers must allow for small equipment charging devices to be plugged in directly and accommodate a variety of sizes.<br/>• The cabinet must be resistant to disinfectants, including the following chemicals: Sodium hypochlorite 10% solution, Isopropanol, industrial methylated spirit (IMS), Formaldehyde, Hydrogen Peroxide, quaternary ammonias and other disinfectants. The cabinet must be able to withstand repeated fumigation using Formaldehyde or Hydrogen Peroxide systems. <br/>• Performance factory quality assurance documentation (e.g final release record form) must be provided, this is to include but not limited to evidence of HEPA integrity, airflows, pressure decay test, restart automatically after power failure. <br/>• The cabinet will be connected to local ventilation systems by means of an exhaust thimble.<br/>• After installation the cabinet must retain all the exhaust air during fumigation degas. This must be confirmed at the commissioning stage.<br/>• The cabinet must be fitted with shut-tight damper (100% gas tight) on both supply and extract for use during fumigation.<br/>• The cabinet must have the option to be bench mounted or stand mounted.<br/>• The cabinet must be subjected to a pressure hold test at commissioning and then every service. This must be carried out at a positive pressure of >250 Pa, and the cabinet must hold pressure to within +/-10% of the test pressure for not less than 30 minutes. DOP scan test must be carried out at a positive pressure of 250 Pa. All joints, seals and penetrations must be scanned as part of the installation at 250 Pa positive pressure. The recorded penetration around all joints, seals and penetrations must be less than 0.003% of the challenge aerosol. <br/>• Cables are not permitted to pass through the containment barrier, all electrical connections though the cabinet walls must be made with fully sealed bulkhead connections. <br/>• The cabinet is expected to run continuously between service intervals for at least 12 months without need for maintenance.<br/>• There will be programable automated fumigation cycles for use with both formaldehyde fumigation systems and hydrogen peroxide, using a Steris hydrogen peroxide generator. This will allow for remote venting of the cabinet and have evidence of the success/failure of cycles, including the cycle times. The fumigation sockets must remain live throughout the cycle.<br/>• The cabinet will be used as an aerosol test chamber and the control system will allow for modifications to the normal operation of the cabinet, this will include allowing for clean work to be undertaken without the fans in operation and independent operation of the fitted dampers.Contract periodNot publishedEligibilityNot publishedOptions / renewalNot published
Timeline
- Procedure published
18 Dec 2023, 18:02 GMT
Commercial outcome and competition
AwardsNo award published |
ContractsNo contract published |
Bid statisticsNo aggregate bid statistics published |
Buyer and organisations in this procedure
Secretary of State for Health and Social Care acting as part of the Crown through UK Health Security Agency
Contracting authority GB-FTS-91907Documents (0)
Official links; attachments are not copied
No linked documents are published
Related procedures (0)
No related procedures published